Maintenance of VISCOTHERM drives
>>>
Periodic checks
>>>
Cooling
>>>
Works revision of pump unit ROTODIFF
>>
General Maintenance for ROTODIFF's
Cooling
|
Recommended working hydraulic oil temperature: 40 - 45 °C. |
|
Where input cooling water temperature is over 20 °C, consult
VISCOTHERM. |
|
Compare inlet and outlet water temperatures of
recommended working oil temperature can not be maintained. In
this case cooler cleaning might be necessary. |
|
If the pump unit is exposed to ambient temperatures below
0 °C ensure that the cooling water does not freeze (empty
cooler or add anti-freeze, ensure continuous circulation). |
Cooler cleaning:
With hard cooling water:
Flush with 5% diluted formic acid. (Caution: after cleaning
the cooler with diluted formic acid flush cooler thoroughly).
With water contaminated with organic substances:
Flush with clean water or if the contamination is persistent
use steam. (Cleaning flush always serval times in the opposite direction
of the normal cooling water flow direction thoroughly).
Caution:
The level- and temperature switch (see our service information
SI-11) exists for emergency situations only. Pump units and ROTODIFF's
witch run above the maximum recommended temperature due to inefficient
cooling will experience high rate of wear, and therefore a short
life-time.
In the case of very dusty, humid or high ambient temperatures in
the operational area, it is advisable to shorten the service interval.
VISCOTHERM will advise.
|
>>Note: |
These are general maintenance advises, various
pump units have additional maintenance instructions.
Please consult the corresponding maintenance manual.
|
|
|